Common Reasons for Failed Inspections

FOOTERS:


FRAMING:






PLUMBING:

MECHANICAL:





FINAL:

GENERAL:


Inadequate Depth
Reinforcement not Supported
Not Maintaining Min 18″ Overlap of Reinforcement
Deck Ledger Attachment (attachment to brick)
Not Providing Lateral Deck Connectors
Lask of Joist Hangers
Post to Beam Connections
Draft Stopping/Fire Blocking
Air Barrier behind Tub on Outside Wall
Cutting. Notching, Boring I-Joists Requires Engineers Letter
Testing DWV and Supply Lines
Lack of Nail Guards, Using Stud Shoes
Elevation of Ductwork in Attic
Protection of Outside Line Set Insulation
Locking Caps on All Access Ports
Not Terminating Exhaust Venting to the Outside
Not Using Listed Tape
Screens on Intake Vents
Graspable Handrails on Stairs
911 Address on Dwellings
Stormwater Violations:
Lack of Silt Fencing
Inadequate Construction Entrance

Upcoming Enforcement for Washington County, Tennessee

DECKS (Section 507):

MECHANICAL:
FIRE PROTECTION FLOORS:

This section includes – Deck footers, Deck Posts Height, Joist spans, Post to Beam Attachment and Deck Ledger Attachment
Dryer Plaque displaying – Where the Equivalent Length exceeds 35′
Any Equipment or Appliance located in crawl space when using I-Joists requires floor protection